Building Codes & Regulations

Tests required for High-rise Building Construction in Kenya

High rise test

Being an

What Defines a High Rise Building in Kenya

Why are Tests Mandatory in High-Rise Construction?

With the enforcement of the National Building Code 2024, Kenya has modernized its approach to construction safety. The code mandates a suite of tests for all high-rise projects, aiming to prevent structural failures and ensure public safety. Non-compliance can lead to severe penalties, including suspension or demolition of non-compliant structures.

Key Entities Involved

EntityRole in High-rise Construction Testing
National Construction Authority (NCA)Regulatory oversight, site inspections, compliance
County GovernmentsPlan approvals, monitoring, and enforcement
Kenya Bureau of Standards (KEBS)Material standards and certifications
Professional Bodies (EBK, BORAQS)Registration and licensing of engineers, architects
Accredited Testing LaboratoriesConducting material and structural tests
 

Civil and Archtectural Tests Required for High-Rise Buildings 

Excavation Stage

Soil Investigation

This is geotechnical inspection that is done to foundation soil before any construction is commenced: They include: 

These tests determine soil bearing capacity, composition, and suitability for supporting tall structures. According to the National Building Code 2024, soil testing is now mandatory for all construction sites, especially high-rise projects.

Groundwater Table Assessment

  • Monitoring Wells
  • Permeability Tests

Understanding groundwater conditions is vital to prevent future settlement or flooding issues.

Related Question:
  • Why is soil testing critical before high-rise construction in Kenya?

    • Soil testing helps engineers design foundations that match site conditions, minimizing risks of collapse or excessive settlement. In Kenya, unstable soils like black cotton require special treatment, as outlined in the new code.

Shoring and Dewatering

Strut Load Test

  • Purpose: Monitors deflection and load on temporary supports during excavation.

  • Significance: Ensures safety of workers and adjacent structures.

Piling

Pile Load Test

  • Static and Dynamic Testing: to validate the bearing capacity of piles.

Pile Integrity Test

  •  Low Strain Testing to detect defects or discontinuities in piles.

Piling Test TypePurposeTypical Equipment Used
Static Load TestVerify ultimate pile capacityHydraulic jacks, load cells
Dynamic Load TestAssess pile behavior under loadDrop hammers, sensors
Integrity TestDetect pile defectsSonic/ultrasonic tools
 

Raft Foundation

Compaction Test

  • Field Density Tests(sand cone or nuclear gauge) ensure soil compaction meets design requirements.

Rebar Inspection

  • Checks for correct spacing, cover, and tying of reinforcement.

Slump and Temperature Test

  • Measures workability and temperature of fresh concrete.

Concrete Cube Test

  • 7 & 28-day compressive strength tests to confirm concrete quality.

Waterproofing Test

  • Fllod/Pond Test: checks for leaks in basement or raft slabs.

Superstructure

Rebar Inspection

  • Conducted for slabs, beams, and columns before concrete placement.

Concrete Cube Test

  • Routine checks for compressive strength.

Pull-out Test

  • Assesses tensile strength of anchors and bolts.

Formwork Check

  • Ensures verticality, stability, and correct dimensions.

Plumb and Level

  • Verifies alignment of core walls and structural elements.

Superstructure TestPurpose
Rebar InspectionPrevents reinforcement errors
Concrete Cube TestEnsures structural strength
Pull-out TestConfirms anchorage performance
Formwork CheckGuarantees dimensional accuracy
Plumb & LevelMaintains building alignment

Architectural tests

Blockwork

  • Mortar Adhesion Test: Checks bond strength between blocks.

  • Alignment and Plumb Check: Ensures straight, vertical walls.

Plastering

  • Thickness Gauge: Verifies plaster thickness.

  • Pull-off Test: Tests adhesion of plaster to substrate.

Tilling and Flooring

  • Moisture Content: Ensures substrate is dry (<4%) before tiling.

  • Tile Adhesion (Pull-out): Confirms tile bonding.

  • FF/FL Test: Measures floor flatness and levelness.

Painting

  • Cross-Cut Test: Assesses paint adhesion.

  • Visual and Thickness Check: Confirms dry film thickness (DFT) and finish quality.

Joinery and Fitouts

  • Installation Tolerances: Checks alignment and hardware fitting.

  • Soft Closing Test: Verifies function of drawers and doors.

Facade and Glazing

  • Water Spray Test (ASTM E1105): Detects façade leakage.

  • Air Tightness Test (ASTM E779 / EN 13829): Measures air permeability.

  • Glass Impact / Sealant Adhesion Test: Ensures safety and durability.

Doors (Including Fire Doors)

  • Drop/Closing Force Test: Checks automatic closing.

  • Gap and Intumescent Seal Check: Ensures fire integrity.

Regulatory Requirements and Approval Process

Step-by-Step Overview

StageKey Entity/OrganizationRequired Documentation
Project RegistrationNational Construction AuthorityContractor/consultant licenses, project details
Plan ApprovalCounty GovernmentArchitectural & structural drawings
Environmental ApprovalNEMAEIA license
Material TestingAccredited Labs (e.g., KEBS)Test reports, certifications
Site InspectionsNCA, County, KEBSInspection reports, compliance certificates
 
MEP

Mechanical, Electrical, and Plumbing (MEP) Tests for High-rise Buildings in Kenya

MEP systems are the lifelines of any high-rise building, ensuring occupant comfort, safety, and operational efficiency. Given Kenya’s rapid urbanization, these systems must undergo rigorous testing to meet the National Building Code and international best practices.

Electrical System Testing 

Test NamePurposeTypical Equipment/Methodology
Insulation Resistance Test (Megger)Ensures electrical insulation integrity to prevent leakage and faultsMegger insulation tester

Continuity Test

Verifies continuous electrical paths for safetyContinuity tester

Functional Test of MDB

Confirms operation of Main Distribution Board components (Switchgear, ACB, MCCB)Visual and operational checks

Primary Injection Test

Tests protection devices like relays and current transformers under loadInjection test sets

Secondary Injection Test

Validates protection relay operation without loadRelay test sets

Contact Resistance Test

Measures resistance in busbar connections to avoid overheatingMicro-ohmmeter

Polarity Test

Ensures correct wiring polarity for safety and functionPolarity testers
 

Why are these tests critical?

Electrical failures can lead to fires, power outages, or equipment damage. The National Construction Authority (NCA) mandates these tests to ensure safety and reliability.
 

HVAC (Heating, Ventilation, and Air Conditioning)

Test NamePurposeNotes

Duct Leakage Test (SMACNA)

Detects air leaks in ductwork to improve efficiencyUses pressure gauges and smoke tests

Air Balancing (TAB Report)

Measures airflow at diffusers to ensure design compliancePerformed by certified technicians

Chiller Test

Checks Coefficient of Performance (COP), flow, and cooling capacityEnsures energy efficiency

Smoke Test

Identifies duct leaks and verifies smoke control systemsCritical for fire safety
 

HVAC testing ensures occupant comfort and energy efficiency, reducing operational costs and improving indoor air quality.

Plumbing System Testing

Test NamePurposeDescription
Hydrostatic Test (Water Supply)Checks pipes and joints for leaks under pressurePipes filled with water, pressurized for 2 hours

Drainage Flow Test

Verifies flow rate, slope, and leak detectionUses water or smoke to detect blockages or leaks
 

Proper plumbing testing prevents water damage, contamination, and system failures.

Fire Fighting Systems Testing

Test NamePurposeDetails

Hydrostatic Test

Tests pipework at 1.5x working pressure for 2 hoursConfirms pipe integrity

Pimp Flow and Pressure Test

Validates fire pump performance under demandEnsures adequate fire suppression
 

Fire safety is paramount in high-rises, with Kenya’s National Fire Safety Code enforcing strict testing protocols.

Fire Alarm System Testing

Test NamePurposeDescription

Loop Integrity Test

Checks resistance and continuity of fire alarm loopsEnsures detection circuits are intact

Device Function Test

Verifies operation of smoke detectors, manual call points (MCPs), sounders, and control panelCritical for early fire detection
 

Building Management System (BMS) Testing

  • Integration Test: Confirms coordination between HVAC, fire alarm, lighting, and security systems.

  • Ensures centralized control and monitoring for operational efficiency.

Lift Testing

Test NamePurposeDetails

Lift Load Test

Verifies capacity and operational safety under full loadConducted with test weights

Safety Gear Test

Checks emergency brakes and safety mechanismsEnsures passenger safety
 

Extra Low Voltage (ELV) Systems Testing

  • CCTV Coverage and Quality: Ensures surveillance meets design specifications.

  • Access Control Test: Verifies functionality of readers, locks, and integration with security systems.

Comprehensive Table: Summary of High-rise Building Tests in Kenya

Construction StageTest TypePurposeResponsible Entity/Personnel
ExcavationSoil InvestigationDetermine soil suitabilityGeotechnical Engineers, Accredited Labs
FoundationPile Load & Integrity TestValidate bearing capacity and pile soundnessStructural Engineers, Testing Labs
Concrete WorkCube & Slump TestsEnsure concrete strength and workabilityQuality Control Teams, Labs
SuperstructureRebar & Formwork InspectionVerify reinforcement and formwork qualitySite Engineers, Inspectors
Electrical SystemsInsulation & Functional TestsConfirm electrical safety and operationElectrical Engineers, Certified Testers
HVACDuct Leakage & Air BalancingEnsure system efficiency and safetyMechanical Engineers, Specialists
PlumbingHydrostatic & Drainage TestsPrevent leaks and ensure flowPlumbing Contractors, Inspectors
Fire SafetyHydrostatic & Alarm TestsGuarantee fire suppression and detectionFire Safety Officers, Inspectors
LiftsLoad & Safety Gear TestsVerify operational safetyLift Engineers, Safety Inspectors
ELV SystemsCCTV & Access Control TestsEnsure security system functionalitySecurity Consultants, Technicians
 

Frequently Asked Questions

What are the penalties for non-compliance with testing requirements in Kenya?

Non-compliance can result in fines, suspension of construction permits, or demolition orders by the NCA or county authorities.

How often should concrete cube tests be conducted during construction?

Typically, samples are taken at regular intervals during concrete pours, with tests conducted at 7 and 28 days to monitor strength development.

Can testing be done by any laboratory in Kenya?

No, tests must be performed by accredited laboratories recognized by KEBS and NCA to ensure validity.

How does the National Building Code 2024 affect testing protocols?

The new code mandates stricter testing and documentation, especially for high-rise buildings, to enhance safety and resilience.

author-avatar

About Festus Nyabuto

Eng. Festus Nyabuto is a Civil Engineer at Criserve Engineering, bringing over four years of professional experience to the role. An alumnus of the University of Nairobi, he complements his engineering expertise with a passion for knowledge sharing, regularly writing and sharing insights on construction topics.